Description
Features and Specifications of Keysight (Agilent/HP) 6050A:
- Specifications:
- AC Input: Three internal switches permit operation from 100, 120, 220, or 240 Vac lines.
- Amplitude: -13% to +6% nominal line voltage
- Frequency: 48 to 63 Hz
- Supplemental Characteristics:
- AC Input: Fuse: The ac input is protected by internal fuses. Maximum VA: 635
- GPIB Programming Command Processing Time (Time required for a GPIB command processed by the Electronic Load): 70 milliseconds (typical)
- GPIB Interface Capabilities: SH1, AH1, T6, L4, SR1, RLI, DT1, DC1
- Trigger Input:
- Vlo = 0.9 V maximum at Ilo = -1 mA
- hi = 3.15 V minimum (pull-up resistor on input)
- Trigger Input:
- Vlo = 0.72 V maximum at Ilo = 1 mA
- Vhi = 4.4 V minimum at Ilo = -20 mA
- Weight:
- Net (mainframe only): Agilent 6050A, 9.5 kg (21 lb.) Agilent 6051A, 5.5 kg (12 lb.)
- Shipping: Agilent 6050A, 14 kg (31 lb.)
- Agilent 6051A, 7.5 kg (17 lb.)
- Dimensions:
- Width: Agilent 6050A, 425.5 mm (16.75 in.) Agilent 6051A, 213 mm (8.4 in.)
- Height: 178 mm (7 in.), add 10 mm (0.4 in.) for removable feet
- Depth: 625 mm (24.6 in.), including input connectors on modules
- GPIB control of current, voltage and resistance
- GPIB readback of current, voltage, and power
- Built-in pulse waveform generation with programmable amplitude, frequency, duty cycle and slew rate
- Full protection from
- Electronic calibration
- Trigger for external synchronization
- Parallel units in constant current mode for higher power
- VXI plug&play drivers
- For complete details, click on the Data Sheet link
The Keysight 6050A electronic load mainframe accepts user-installable Keysight load modules for easy system configuration and future reconfiguration. The 6051A holds up to two 60501B, 60502B, 60503B modules, or one 60504B or 60507B module allowing up to 600 watts of total maximum power. One GPIB address is all you need for complete control and readback of all modules within a single mainframe.